313 research outputs found

    Identification and quantification of prosthetic mitral regurgitation by flow convergence method using transthoracic approach

    Get PDF
    The present case report illustrates the clinical applicability of the proximal isovelocity surface area (PISA) method in identifying, locating and assessing paravalvular prosthetic mitral regurgitation by transthoracic echocardiography

    Comparison of m-mode echocardiographic left ventricular mass measured using digital and strip chart readings: The Atherosclerosis Risk in Communities (ARIC) study

    Get PDF
    BACKGROUND: Epidemiological and clinical studies frequently use echocardiography to measure LV wall thicknesses and chamber dimension for estimating quantitative measures of LV mass. While echocardiographic M-mode LV images have traditionally been measured using hand-held calipers and strip-chart paper tracings, digitized M-mode LV image measurements made directly on the computer screen using electronic calipers have become standard practice. We sought to determine if systematic differences in LV mass occur between the two methods by comparing LV mass measured from simultaneous M-mode strip chart recordings and digitized recordings. METHODS: The Atherosclerosis Risk in Communities study applied the latter method. To determine if systematic differences in LV mass occur between the two methods, LV mass was measured from simultaneous M-mode strip chart recordings and digitized recordings. RESULTS: We found no difference in LV mass (p > .25) and a strong correlation in LV mass between the two methods (r = 0.97). Neither age, sex, nor hypertension status affected the correlation of LV mass between the two methods. CONCLUSIONS: We conclude that digital estimates of LV mass provide unbiased estimates comparable to the strip-chart method

    Velocity vector imaging to quantify left atrial function

    Get PDF
    The aim of our study was to assess the feasibility of a new image analysis, velocity vector imaging (VVI), in the assessment of left atrial volumes (LAV) and left atrial ejection fraction (LAEF). We retrospectively analysed 100 transthoracic echocardiographic findings in 71 men, and 29 women (mean age 57 ± 19.8 years). Two subgroups of patients were defined: (1) with left ventricular (LV) EF > 50%, and (2) LV EF < 50%. For the VVI method of indexed LAV assessment we used the apical four-chamber view. From the displacement of LA endocardial pixels time–volume curves were extracted which provided automatically data regarding indexed maximum LAV (LAVImax), indexed minimum LAV (LAVImin), and LAEF. LAVs and LAEF by 2-dimensional echocardiograhy (2DE) were measured by Simpson’s biplane disc summation method. Comparing LAVImax, LAVImin, and LAEF by VVI versus 2DE in the total study population, we found significant correlations: r = 0.94, P < 0.0001, r = 0.94, P < 0.0001, r = 0.79, P < 0.0001, respectively. In addition, LAVImax ≥ 40 ml/m2 was 94% sensitive and 72% specific, LAVImin ≥ 27 ml/m2 was 90% sensitive and 86% specific, and LAEF < 30% was 80% sensitive and 96% specific for the detection of LV systolic dysfunction. There were highly significant inverse associations of LAVImax and LAVImin to LVEF. LAEF was also significantly related to LV systolic function. When comparing the time required for VVI and 2DE measurements, VVI led to 62% reduction in the measurement time. In conclusion, VVI is a feasible method for the assessment of LAVs and LAEF. It provides close agreement with that measured by conventional 2DE Simpson’s biplane method with significant time saved

    Left atrioventricular remodeling in the assessment of the left ventricle diastolic function in patients with heart failure: a review of the currently studied echocardiographic variables

    Get PDF
    Multiparametric echocardiographic imaging of the failing heart is now increasingly used and useful in decision making in heart failure. The reasons for this, relies on the need of different strategies of handling these patients, as differentiation of systolic or diastolic dysfunction, as well as on the gamma of approaches available, such as percutaneous and surgical revascularization, devices implantations, and valvular regurgitations and stenosis corrections. Congestive heart failure in patients with normal left ventricular diameters or preserved left ventricular ejection fraction had been pointed out recently as present in a proportion so high as 40 to 50 percent of cases of heart failure, mainly due to the epidemics in well developed countries, as is the problem of not well controlled metabolic states (such as obesity and diabetes), but also due to the real word in developing countries, as is the case of hypertension epidemics and its lack of adequate control. As a matter of public utility, the guidelines in the diagnosis and treatment of such patients will have to be cheap, available, easily reproducible, and ideally will furnish answers for the clinician questions not in a binary "black or white" manner, but with graduations, so if possible it has to be quantitative. The present paper aim to focus on the current clinical applications of tissue Doppler and of left atrial function and remodeling, and its pathophysiologic relationship with the left ventricle, as will be cleared in the documented review of echocardiography that follows, considering that the need of universal data on the syndrome of the failing heart does not mean, unfortunately, that all patients and clinicians in developing countries have at their own health facilities the same imaging tools, since they are, as a general rule, expensive

    Prevalence of left ventricular diastolic dysfunction in European populations based on cross-validated diagnostic thresholds

    Get PDF
    BACKGROUND: Different diagnostic criteria limit comparisons between populations in the prevalence of diastolic left ventricular (LV) dysfunction. We aimed to compare across populations age-specific echocardiographic criteria for diastolic LV dysfunction as well as their correlates and prevalence. METHODS: We measured the E and A peaks of transmitral blood flow by pulsed wave Doppler and the e' and a' peaks of mitral annular velocities by tissue Doppler imaging (TDI) in 2 cohorts randomly recruited in Belgium (n = 782; 51.4% women; mean age, 51.1 years) and in Italy, Poland and Russia (n = 476; 55.7%; 44.5 years). RESULTS: In stepwise regression, the multivariable-adjusted correlates of the transmitral and TDI diastolic indexes were similar in the 2 cohorts and included sex, age, body mass index, blood pressure and heart rate. Similarly, cut-off limits for the E/A ratio (2.5th percentile) and E/e' ratio (97.5th percentile) in 338 and 185 reference subjects free from cardiovascular risk factors respectively selected from both cohorts were consistent within 0.02 and 0.26 units (median across 5 age groups). The rounded 2.5th percentile of the E/A ratio decreased by ~0.10 per age decade in these apparently healthy subjects. The reference subsample provided age-specific cut-off limits for normal E/A and E/e' ratios. In the 2 cohorts combined, diastolic dysfunction groups 1 (impaired relaxation), 2 (possible elevated LV filling pressure) and 3 (elevated E/e' and abnormally low E/A) encompassed 114 (9.1%), 135 (10.7%), and 40 (3.2%) subjects, respectively. CONCLUSIONS: The age-specific criteria for diastolic LV dysfunction were highly consistent across the study populations with an age-standardized prevalence of 22.4% vs. 25.1%

    The heart in sporadic inclusion body myositis: a study in 51 patients

    Get PDF
    The purpose of this study was to explore the prevalence and nature of cardiac abnormalities in sporadic inclusion body myositis (sIBM). Fifty-one sIBM patients were cross-sectionally studied using history-taking, physical examination, measurements of serum creatine kinase activity, the MB fraction (CK-MB), cardiac troponin T (cTnT) and I (cTnI), a 12-lead electrocardiogram (ECG) and 2-dimensional echocardiography. Present cardiac history was abnormal in 12 (24%) out of 51 patients, 12 (24%) patients had abnormalities on ECG, mostly aspecific, and in 12 (24%) patients the echocardiograph showed abnormalities. Elevated CK-MB was present in 42 (82%) patients and 40 (78%) had an elevated cTnT in the absence of acute cardiac pathology. In contrast, in one patient (2%) cTnI was elevated. There was no apparent association between elevated biomarkers, ECG or echocardiographic abnormalities. The prevalence of cardiac abnormalities in sIBM does not seem to be higher than would be expected in these elderly patients. Elevated CK-MB and cTnT levels are common, in contrast to cTnI, but do not reflect cardiac pathology

    Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    Get PDF
    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data

    The Effect of Prolonged Physical Activity Performed during Extreme Caloric Deprivation on Cardiac Function

    Get PDF
    Background: Endurance exercise may induce transient cardiac dysfunction. Data regarding the effect of caloric restriction on cardiac function is limited. We studied the effect of physical activity performed during extreme caloric deprivation on cardiac function. Methods: Thirty-nine healthy male soldiers (mean age 2060.3 years) were studied during a field training exercise lasted 85– 103 hours, with negligible food intake and unlimited water supply. Anthropometric measurements, echocardiographic examinations and blood and urine tests were performed before and after the training exercise. Results: Baseline VO2 max was 5965.5 ml/kg/min. Participants ’ mean weight reduction was 5.760.9 kg. There was an increase in plasma urea (11.662.6 to 15.863.8 mmol/L, p,0.001) and urine osmolarity (6926212 to 10946140 mmol/kg, p,0.001) and a decrease in sodium levels (140.561.0 to 136.662.1 mmol/L, p,0.001) at the end of the study. Significant alterations in diastolic parameters included a decrease in mitral E wave (93.6 to 83.5 cm/s; p = 0.003), without change in E/A and E/E9 ratios, and an increase in iso-volumic relaxation time (73.9 to 82.9 ms, p = 0.006). There was no change in left or right ventricular systolic function, or pulmonary arterial pressure. Brain natriuretic peptide (BNP) levels were significantly reduced post-training (median 9 to 0 pg/ml, p,0.001). There was no elevation in Troponin T or CRP levels. On multivariate analysis, BNP reduction correlated with sodium levels and weight reduction (R = 0.8, p,0.001)

    Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent studies have shown that real-time three-dimensional (3D) echocardiography (RT3DE) gives more accurate and reproducible left ventricular (LV) volume and ejection fraction (EF) measurements than traditional two-dimensional methods. A new semi-automated tool (4DLVQ) for volume measurements in RT3DE has been developed. We sought to evaluate the accuracy and repeatability of this method compared to a 3D echo standard.</p> <p>Methods</p> <p>LV end-diastolic volumes (EDV), end-systolic volumes (ESV), and EF measured using 4DLVQ were compared with a commercially available semi-automated analysis tool (TomTec 4D LV-Analysis ver. 2.2) in 35 patients. Repeated measurements were performed to investigate inter- and intra-observer variability.</p> <p>Results</p> <p>Average analysis time of the new tool was 141s, significantly shorter than 261s using TomTec (<it>p </it>< 0.001). Bland Altman analysis revealed high agreement of measured EDV, ESV, and EF compared to TomTec (<it>p </it>= <it>NS</it>), with bias and 95% limits of agreement of 2.1 ± 21 ml, -0.88 ± 17 ml, and 1.6 ± 11% for EDV, ESV, and EF respectively. Intra-observer variability of 4DLVQ vs. TomTec was 7.5 ± 6.2 ml vs. 7.7 ± 7.3 ml for EDV, 5.5 ± 5.6 ml vs. 5.0 ± 5.9 ml for ESV, and 3.0 ± 2.7% vs. 2.1 ± 2.0% for EF (<it>p </it>= <it>NS</it>). The inter-observer variability of 4DLVQ vs. TomTec was 9.0 ± 5.9 ml vs. 17 ± 6.3 ml for EDV (<it>p </it>< 0.05), 5.0 ± 3.6 ml vs. 12 ± 7.7 ml for ESV (<it>p </it>< 0.05), and 2.7 ± 2.8% vs. 3.0 ± 2.1% for EF (<it>p </it>= <it>NS</it>).</p> <p>Conclusion</p> <p>In conclusion, the new analysis tool gives rapid and reproducible measurements of LV volumes and EF, with good agreement compared to another RT3DE volume quantification tool.</p
    corecore